Temperature Dependent Electrical Impedance Characteristics for Porcine Liver in Vitro(PDF)

《南京师大学报(自然科学版)》[ISSN:1001-4616/CN:32-1239/N]

Issue:
2012年02期
Page:
32-38
Research Field:
物理学
Publishing date:

Info

Title:
Temperature Dependent Electrical Impedance Characteristics for Porcine Liver in Vitro
Author(s):
Chen Xuanze12Ma Qingyu1Yang Ling1Zhang Feng1
1.School of Physics and Technology,Nanjing Normal University,Nanjing 210046,China
Keywords:
porcine liver tissueelectrical impedancetemperaturehigh intensity focused ultrasound
PACS:
R312;R730.5
DOI:
-
Abstract:
In order to achieve inhibiting or killing cancer cells without the damage to the normal tissue in high intensity focused ultrasound ( HIFU) treatment,an precise real-time temperature monitoring system should be set up. The purpose of this study is to obtain the temperature dependent electrical impedance characteristics for accurate power control for HIFU application. Combined with the micrographs of porcine liver tissues,it is proved that there is an obvious temperature and heating duration time dependent relation of the electrical impedance characteristics and the electrical impedance decreases with the increasing of temperature. When porcine liver tissue is heated to cell inactivation and tissue coagulation for long time slow heating at 56℃ or short time fast heating at 73℃,significant electrical impedance change occurs with the critical properties. The favorable results provide the basis for further temperature monitoring in HIFU treatment process using the proposed electrical impedance measurement approach.

References:

[1] Wu Feng,Wang Zhibiao,Chen Wenzhi,et al. Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China: an overview [J]. Ultrasonics Sonochemistry,2004,11( 3 /4) : 149-154.
[2] Thuroff S,Chaussy C,Vallancien G,et al. High-intensity focused ultrasound and localized prostate cancer: efficacy results from the European multicentric study [J]. Journal of Endourology,2003,17( 8) : 8-16.
[3] Stewart E,Gedroyc W,Tempany C,et al. Focused ultrasound treatment of uterine fibroids: safety and feasibility of a noninvasive thermoablative technique [J]. Am J Obstet Gynecol,2003,189( 1) : 48-54.
[4] 冯若,朱辉,皱建中. 高强度聚焦超声( HIFU) 技术迅速发展的五年[J]. 声学技术,2006,25( 4) : 387-389.
[5] Lynn J G,Zwemer R L,Chick A J,et al. A new method for the generation and use of focused ultrasound in experimental biology [J]. J Gen Physiol,1942,26( 2) : 179-193.
[6] Fry W J,Mosberg W H,Bamard J W,et al. Production of focal destructive lesions in the central nervous system with ultrasound [J]. J Neurosurg,1954,11( 5) : 471-478.
[7] 林世寅,李瑞英. 现代肿瘤热疗学———原理、方法与临床[M]. 北京: 学苑出版社, 1997: 185-202.
[8] Paulsen K,Moskowitz M,Ryan T,et al. Initial in vivo experience with EIT as a thermal estimator during hyperthermia[J]. Int J Hyperthermia,1996,12( 5) : 573-591.
[9] Young I R,Hand J W,Oatridge A,et al. Modeling and observation of temperature changes in vivo using MRI [J]. Magn Reson Med,1994,32( 1) : 358-369.[10] Wu S C,Bai Y P,Nan Q,et al. The research on method of noninvasive temperature estimation in hyperthermia [J]. Foreign Medical Sciences: Biomedical Engineering Fascicle,2002,25( 1) : 35-38.
[11] 赵硕峰,王智运,邓亲恺,等. 家猪骨与软组织电阻抗特性研究[J]. 中国医疗设备, 2011,6( 4) : 17-21.
[12] Blad B,Persson B,Lindstrom K. Quantitative assessment of impedance tomography for temperature measurements in hyperthermia [J]. International Journal of Hyperthermia,1992,8( 1) : 33-43.
[13] Paulsen K D,Moskowitz M J,Ryan T P,et al. Initial in vivo experience with EIT as a thermal estimator during hyperthermia [J]. Int J Hyperthermia,1996,12( 5) : 573-591.
[14] Griffiths H,Ahmed A. Applied potential tomography for noninvasive temperature mapping in hyperthermia [J]. Clin Phys Physiol Meas,1987( 8) : 147-153.[15] Conway J. Electrical impedance tomography for thermal monitoring of hyperthermia treatment an assessment using in vitro and in vivo measurements[J]. Clin Phys Physiol Meas,1987( 8) : 141-146.
[16] Cole K S,Cole R H,Dispersion and absorption in dielectrics[J]. J Chem phys,1941,9( 4) : 341-351.
[17] Geddes L A,Baker L E. Principles of Applied Biomedical Instrumentation[M]. New York: John Wiley & Sons,1968.[18] 班东坡. 人体电阻抗测量系统设计[D]. 天津: 天津大学生物医学工程系, 2003.
[19] Polczynski M H,Seitz M A. Low-frequency 4-probe impedance measuring system[J]. Med & Biol Eng & Comput,1979, 15( 6) : 573-576.
[20] Tang Min. The principle and technique of bio-impedance measurements [J]. J Biomed Eng,1997,14( 2) : 152-155.
[21] Noshiro M,Morimoto T,Nagao H,et al. Electrical impedance in the lower limbs of patients with duchenne muscular dystrophy: a preliminary study[J]. Medical & Biological Engineering & Computing,1993,31( 2) : 97-102.
[22] 蔡华,尤富生,史学涛. 兔离体新鲜肝组织的电阻抗温度特性研究[J]. 医疗卫生装备,2010,31( 11) : 8-11.
[23] 石军,熊六林. 45℃ ~ 60℃高温对活体猪肝脏损伤效果的实验研究[J]. 中国普外基础与临床杂志,2008, 15( 7) : 494-497.

Memo

Memo:
-
Last Update: 2013-03-11