[1]杨红晓,张林群,周爱东.等离子光谱法测定岩石中微量元素的不确定度评定[J].南京师大学报(自然科学版),2011,34(03):69-73.
 Yang Hongxiao,Zhang Linqun,Zhou Aidong.Uncertainty Evaluation for Determination of Trace Elements in Rock by Inductively Coupled Plasma Atomic Emission Spectrometry[J].Journal of Nanjing Normal University(Natural Science Edition),2011,34(03):69-73.
点击复制

等离子光谱法测定岩石中微量元素的不确定度评定()
分享到:

《南京师大学报(自然科学版)》[ISSN:1001-4616/CN:32-1239/N]

卷:
第34卷
期数:
2011年03期
页码:
69-73
栏目:
化学
出版日期:
2011-09-20

文章信息/Info

Title:
Uncertainty Evaluation for Determination of Trace Elements in Rock by Inductively Coupled Plasma Atomic Emission Spectrometry
作者:
杨红晓1张林群1周爱东2
( 1. 南京师范大学分析测试中心,江苏南京210046) ( 2. 南京大学化学化工学院,江苏南京210093)
Author(s):
Yang Hongxiao1Zhang Linqun1Zhou Aidong2
1.Analysis & Testing Center,Nanjing Normal University,Nanjing 210046,China
关键词:
不确定度评定等离子体发射光谱法微量元素岩石
Keywords:
uncertainty evaluationinductively coupled plasma atomic emission spectrometry ( ICP-AES) trace elements rock
分类号:
P575.4;O657.31
摘要:
对电感耦合等离子体原子发射光谱(ICP-AES)法测定岩石中6个微量元素Cu、Zn、Pb、Mn、Ni、Cr的不确定度来源进行了详细分析.不确定度的来源主要包括分析过程中所用的天平、玻璃器皿、标准曲线、标准溶液、试液定容体积及测量重复性等引入的不确定度分量.计算出各分量的不确定度,最后合成标准不确定度、扩展不确定度,得出测试结果的报告形式.
Abstract:
The sources for the uncertainty were analyzed in detail for the determination of trace elements including copper, zinc,plumbum,manganese,nickel,and chromium in rock by inductively coupled plasma atomic emission spectrometric method. The main sources of measurement uncertainty come from sub-uncertainties of the analytical balance,analytical glassware,calibration curves,calibration solutions,reagent volume and repetitive measurements. Each sub - uncertainty, combined uncertainty and expanded uncertainty of the measurement results were calculated,and the report form of testing result was obtained.

参考文献/References:

[1] 中国实验室国家认可委员会. 化学分析中不确定度的评估指南[M]. 北京: 中国计量出版社, 2002: 2-20.
[2] 国家质量技术监督局计量司组. 测量不确定度评估与表达指南[M]. 北京: 中国计量出版社, 2000: 5-10.
[3] 王斗文,韩大卫,于华. 电感耦合等离子体原子发射光谱法测定金属硅中铁含量的不确定度评估[J]. 计量学报, 2005,26( 1) : 93-96.
[4] 李宣,李孟仁,江丽媛,等. ICP-AES 法测定油漆中总铅量不确定度的讨论[J]. 理化检验: 化学分册, 2005,41( 11) : 837-839.
[5] 刘翠平,夏碧琪. ICP-AES 测定塑料中的镉的不确定度评估[J]. 光谱实验室, 2007,24( 2) : 73-77.
[6] 何志明. 电感耦合等离子体原子发射光谱法测定低合金钢中铜的不确定度评定[J]. 冶金分析, 2009,29( 10) : 76- 80.
[7] 中国计量科学研究院. JJF1059,1999,测量不确定度评定与表示[S]. 北京: 中国计量出版社, 1999.
[8] 上海市计量技术研究所. JJG196,1990,常用玻璃量具[S]. 北京: 中国计量出版社, 1990.

备注/Memo

备注/Memo:
基金项目:国家自然科学基金面上预研资助项目( 1116020501) .通讯联系人:周爱东,博士,副教授,研究方向: 应用化学. E-mail: zhouad@ nju. edu. Cn