[1]丁鹤平,宿慧丹,马青玉,等.高强度聚焦超声治疗中基于电阻抗相对变化的组织温度监测技术[J].南京师范大学学报(自然科学版),2018,41(02):39.[doi:10.3969/j.issn.1001-4616.2018.02.008]
 Ding Heping,Su Huidan,Ma Qingyu,et al.Relative Electrical Impedance Variation Based Temperature MonitoringTechnology for High Intensity Focused Ultrasound Therapy[J].Journal of Nanjing Normal University(Natural Science Edition),2018,41(02):39.[doi:10.3969/j.issn.1001-4616.2018.02.008]
点击复制

高强度聚焦超声治疗中基于电阻抗相对变化的组织温度监测技术()
分享到:

《南京师范大学学报》(自然科学版)[ISSN:1001-4616/CN:32-1239/N]

卷:
第41卷
期数:
2018年02期
页码:
39
栏目:
·物理学·
出版日期:
2018-06-30

文章信息/Info

Title:
Relative Electrical Impedance Variation Based Temperature MonitoringTechnology for High Intensity Focused Ultrasound Therapy
文章编号:
1001-4616(2018)02-0039-08
作者:
丁鹤平宿慧丹马青玉郭各朴
南京师范大学物理科学与技术学院,江苏 南京 210023
Author(s):
Ding HepingSu HuidanMa QingyuGuo Gepu
School of Physics and Technology,Nanjing Normal University,Nanjing 210023,China
关键词:
高强度聚焦超声电阻抗相对变化焦域电导率分布温度监测
Keywords:
high intensity focused ultrasoundrelative electrical impedance variationfocal conductivity distributiontemperature monitoring
分类号:
O426.2
DOI:
10.3969/j.issn.1001-4616.2018.02.008
文献标志码:
A
摘要:
高强度聚焦超声(HIFU)通过聚焦超声的声热效应对肿瘤组织进行局部快速的热疗,是一种非侵入性的无创肿瘤治疗新技术,而其治疗过程中温度监测是HIFU治疗中剂量精准控制的关键. 本文基于HIFU的声传播基本原理,建立了HIFU治疗和组织电阻抗测量的模型,数值模拟了治疗过程中焦域的声场、温度场和电导率分布,并通过电势和电流密度分布的变化,计算了模型的电阻抗的整体变化,结果表明在一个规定的HIFU声功率作用下,组织模型的电阻抗相对变化和治疗时间呈线性关系,其电阻抗相对变化率和HIFU声功率也呈线性关系. 按照仿真条件,建立了HIFU治疗和电阻抗实时测量的联合实验系统,在不同声功率和治疗时间条件下,对组织模型的电阻抗相对变化进行了测量,实验结果和理论仿真结果基本一致. 研究结果证明用电阻抗相对变化进行HIFU治疗中焦域温度监控的可行性,为其疗效检测和剂量控制提供了新方法.
Abstract:
High intensity focused ultrasound(HIFU)can kill the tumor cells with the acousto-thermo-coagulation effects in the focal region,and it is considered to be the noninvasive technology for therapy. Based on the principle of acoustic transmission for HIFU,a composite model of HIFU therapy and electrical impedance measurement is established. Numerical studies for the distributions of the acoustic,temperature and conductivity fields in the focal region are conducted and the relative variations of the electrical impedance of the model are also achieved. It is proved that,for a fixed acoustic power,the relative impedance variation(RIV)shows a linear relationship with the treatment time and the rate of RIV increases linearly with the increase of the acoustic power. With the experimental setup,the measurements of the electrical impedance of the model are performed during the HIFU therapy,and good agreements to the simulation results are achieved. The favorable results verify the feasibility of noninvasive temperature monitoring using the RIV and also provide a new method for efficacy detection and dose control for HIFU therapy.

参考文献/References:

[1] KENNEDY J E. High-intensity focused ultrasound in the treatment of solid tumours[J]. Nat Rev Cancer,2005,5:321-327.
[2]XING Y F,LU X C,PUS E C,et al. The Effect of high intensity focused ultrasound treatment on metastases in a Murine Melanoma model[J]. Biochem Biophys Res Commun,2008,375:645-650.
[3]JOLESZ F A,MCDANNOLD N. Current status and future potential of MRI-guided focused ultrasound surgery[J]. J Magn Reson Imag,2008,27:391-399.
[4]YE G,SMITH P P,NOBLE J A. Model-based ultrasound temperature visualization and following HIFU Exposure[J]. Ultrasound Med Biol,2010,36:234-249.
[5]QIAN Z W,YU J S,FEI X B,et al. Noninvasive temperature monitoring in HIFU clinical uses[J]. Int J Hyperthermia,2005,21:589-600.[6]DANIELS M J,VARGHESE T,MADSEN E L,et al. Non-invasive ultrasound-based temperature imaging for monitoring radiofrequency heating-phantom results[J]. Phys Med Biol,2007,52:4 827-4 843.
[7]MA Y,ZHANG D,GONG X F,et al. Noninvasive temperature estimation by detecting echo-strain change including thermal expansion[J]. Chin Phys,2007,16:2745-2751.
[8]ANAND A. Noninvasive temperature estimation technique for HIFU therapy monitoring using backscattered ultrasound[D]. Seattle:University of Washington,2005.
[9]GABRIEL C,PENMAN A,GRANT E H. Electrical conductivity of tissue at frequencies below 1 MHz[J]. Phys Med Biol,2009,54:4863-4878.
[10]ZURBUCHEN U,HOLMER C,LEHMANN K S,et al. Determination of the temperature-dependent electric conductivity of liver tissue ex vivo and in vivo:importance for therapy planning for the radio frequency ablation of liver tumours[J]. Int J Hyperthermia,2010,26:26-33.
[11]蔡华,尤富生,史学涛,等. 兔离体新鲜肝组织的电阻抗温度特性研究[J]. 医疗卫生装备,2010,11:8-11.
[12]李发琪,张樯,杜永洪,等. 高强度聚焦超声治疗剂量对组织温升影响的研究[J]. 生物医学工程学杂志,2003,3:466-471.
[13]BORCEA L. Electrical impedance tomography[J]. Inverse problems,2002,18:R99-R136.
[14]BLACKSTOCK D T. Fundamentals of physical acoustics[M]. New York:John Wiley & Sons Inc,2000.
[15]范庭波. 高强度聚焦超声非线性声场和组织损伤形成的扫描模式比较研究[D]. 南京:南京大学,2012.
[16]PENNES H H. Analysis of tissue and arterial blood temperatures in the resting human forearm[J]. J Appl Physiol,1948,1:93-122.
[17]郭各朴,宿慧丹,丁鹤平,等. 基于电阻抗层析成像的高强度聚焦超声温度监测技术[J]. 物理学报,2017,66:164301.
[18]TAKEGAMI K,KANEKO Y,WATANABE T,et al. Polyacrylamide gel containing egg white as new model for irradiation experiments using focused ultrasound[J]. Ultrasound Med Biol,2004,30:1419-1422.
[19]胡兵,姜立新,黄瑛. 用于高强度聚焦超声热消融的PAA模块:模块的制作及声学参数的测量[J]. 声学技术,2006,6:613-616.
[20]TAO C Y,GUO G P,MA Q Y,et al. Accurate acoustic power measurement for low intensity focused ultrasound using focal axial vibration velocity[J]. J App Phys,2017,122(1):014 901.
[21]宿慧丹,戴思捷,郭各朴,等. HIFU焦域的温度分布模拟及其疗效分析[J]. 南京师大学报(自然科学版),2017,40:144-150.
[22]SU H D,GUO G P,MA Q Y,et al. Noninvasive treatment efficacy monitoring and dose control for high intensity focused ultrasound therapy using relative electrical impedance variation[J]. Chinese Physics B,2017,26(5):054302.
[23]MYERS M R,SONESON J E. Temperature modes for nonlinear Gaussian beams[J]. Journal of the acoustical society of America,2009,126(1):425-433.
[24]SONESON J E,MYERS M R. Gaussian representation of high-intensity focused ultrasound beams[J]. Journal of the acoustical society of America,2007,122(5):2526-2531.

相似文献/References:

[1]陈轩泽,马青玉,杨玲,等.离体猪肝组织电阻抗的温度特性研究[J].南京师范大学学报(自然科学版),2012,35(02):32.
 Chen Xuanze,Ma Qingyu,Yang Ling,et al.Temperature Dependent Electrical Impedance Characteristics for Porcine Liver in Vitro[J].Journal of Nanjing Normal University(Natural Science Edition),2012,35(02):32.
[2]何向东,冯少彤.高强度聚焦超声温度场的有限差分模拟[J].南京师范大学学报(自然科学版),2015,38(04):106.
 He Xiangdong,Feng Shaotong.Temperature Field Simulation for High Intensity Focused Ultrasound(HIFU)Using Finite Difference Method in Time Domain(FDTD)[J].Journal of Nanjing Normal University(Natural Science Edition),2015,38(02):106.

备注/Memo

备注/Memo:
收稿日期:2018-01-08.
基金项目:国家自然科学基金(11474166,11604156)、江苏省自然科学基金(BK20161013)、中国博士后科学基金(2016M591874)、江苏高校优势学科建设项目.
通讯联系人:马青玉,博士,教授,研究方向:电子技术、信息处理和声学. E-mail:maqingyu@njnu.edu.cn
更新日期/Last Update: 2018-11-06